[F106] Point and Print partition damage
(1) Turn the power OFF and start up the Setting Mode (08).
(2) Key in “662” and press the [START] button. (Partition clearing is performed.)
(3) Restart the equipment.
(4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open.
Then install the “Point and Print” driver.
[F107] / SHR partition damage
Initialize the Electronic Filing using the Setting Mode (08-666).
[F108] /SHA partition damage
Initialize the shared folder using the Setting Mode (08-667).
[F120] Database abnormality
(1) Rebuild the databases. (Perform 08-684.)
(2) If the error is not recovered, initialize the HDD. (Key in “2” at 08-690.)
[F130] Invalid MAC address (e-STUDIO352/353/452/453)
Compare the serial number of the equipment with a number displayed in 08-995. If they are different,
enter the correct serial number at 08-995.
[F200] Data overwrite kit (GP-1050) is taken off
(e-STUDIO350/450)
Clear the service call “F200”. (Key in “0” at 08-633.)
* When the Data overwrite kit (GP-1050) is removed from the equipment, the service call “F200”
occurs.
[
F200] Data overwrite kit (GP-1060) is taken off (e-STUDIO352/353/452/453)
Check the system ROM version (08-900) since the countermeasure to be taken varies.
T364SY0*329 or later
(* represents a letter of the alphabet corresponding to the destination.)
Download the system firmware again.
P. 6-1 "6. FIRMWARE UPDATING"
Earlier than T364SY0*329
(* represents a letter of the alphabet corresponding to the destination.)
Clear the service call “F200”. (Key in “0” at 08-633.)
* When the Data overwrite kit (GP-1060) is removed from the equipment, the service call “F200”
occurs.