TROUBLESHOOTING
5 - 119
5
11) Skew (inclined image)
Defective area
Step
Check items
Prescription
Drawers LCF
1
Is the drawer or LCF properly
installed?
Install the drawer or LCF properly.
2
Is there too much paper in the
drawer or LCF?
Reduce paper to 550 sheets or less. (2500
sheets or less/stack for LCF)
3
Is the corner of the paper folded?
Change the direction of the paper and set
it again.
4
Are the side guides of the drawer or
LCF properly installed?
Adjust the position of the side guides.
Feed roller
5
Is the surface of the feed roller dirty? Clean the roller surface with alcohol, or
replace the roller.
Rollers
6
Are the roller and shaft secured?
Check and tighten the E-rings, pins, clips
and setscrews.
Registration roller
7
Is the spring detached from the reg-
istration roller?
Attach the spring correctly. Clean the roller
if it is dirty.
Pre-registration
guide
8
Is the pre-registration guide properly
installed?
Correct it.
Carriage-1
9
Is the carriage-1 slanted?
Adjust the carriage-1.
Feeding direction
05/11