e-STUDIO350/352/353/450/452/453
FIRMWARE UPDATING
6 - 5
6
6.1.1
PWA-DWNLD-350-JIG2 (48 MB)
The master data written on the hard disk can be updated by using PWA-DWNLD-350-JIG2 (48 MB).
Update the master data according to the need such as the case of replacing the hard disk.
The data to be overwritten are as follows.
• HDD program data (RIP data, list data, Web data, filing box control data)
• UI data (fixed section data, common section data, the language 1 to 7 data, the language 1 to 6 data
for Web)
[A] Update procedure
Important:
• Use the download jig “PWA-DWNLD-350-JIG2 (48 MB)”.
• Turn OFF the power before installing and removing the download jig.
• Do not turn OFF the power during the update. The data could be damaged and not be oper-
ated properly.
(1) Write the data to the download jig.
P. 6-20 "6.1.3 Writing the data to the download jig (PWA-DWNLD-350-JIG)"
(2) Turn OFF the power of the equipment.
(3) Take off the connector cover.
Fig. 6-4
Connector cover