© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
FIRMWARE UPDATING
6 - 23
6
(3) Take off the connector cover.
Fig. 6-12
(4) Remove the cover plate.
Fig. 6-13
(5) Connect the download jig with the jig connector (CN344) on the logic PC board (LGC board).
Fig. 6-14
(6) Turn ON the power while [0] button and [8] button are pressed simultaneously.
Updating starts automatically and the LED on the download jig lights.
Connector cover
Cover plate
Connector