“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com-
pleted properly. “Failed” appears next to the failed item on the status display. Turn OFF the
power, and then check the following items. After confirming and cleaning the problems, restart
updating from the beginning.
• Is the download jig connected properly?
• Is the updating data written to the download jig properly?
• Do the download jig and the equipment operate properly?
When the FROM basic section software version to be updated is "V1.00 / 1.12" or earlier:
Fig. 6-40
When the FROM basic section software version to be updated is "V1.00 / 4.22" or later:
Fig. 6-41
(9) Turn OFF the power, remove the download jig and install the cover plate and the connector
cover.
(10) Perform the initialization of the updating data.
• Turn ON the power while [0] button and [8] button are pressed simultaneously.
• Key in “947”, and then press the [START] button.
• Press the [INITIALIZE] button.