© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 45
2
2.2.4
Test print mode (test mode 04)
<Operation procedure>
Notes:
1. When an error occurs, it is indicated on the panel, but the recovery operation is not per-
formed. Turn OFF the power and then back ON to clear the error.
2. During test printing, the [CLEAR] button is disabled when “Wait adding toner” is displayed.
The embedded test pattern can be printed out by keying in the following codes in the test print mode (04).
Code
Types of test pattern
Remarks
111
Primary scanning direction 33 gradation steps
Error diffusion
113
Secondary scanning direction 33 gradation steps Error diffusion
142
Grid pattern
Pattern width: 2 dots, Pitch: 10 mm
[0][4]
[POWER]
[POWER] OFF/ON
(Exit)
(Code)
[START]
[CLEAR]
Operation
Continuous
Test Printing
05/12