FIRMWARE UPDATING
6 - 79
6
6.4
Firmware Updating with USB Storage Device
(e-STUDIO350/450)
In this equipment, it is feasible to update the firmware by connecting the USB storage device on which
the firmware data is written to the USB connector mounted on the system control PC board and turning
ON the power.
The type of firmware to be updated can be selected on the LCD screen in this method. This allows to
update only the necessary firmware individually or to update all firmware in a batch. The type of firm-
ware which can be updated with this method are as follows in the table below. Also, the data file of each
firmware can be used commonly in the updating methods with USB storage device and Download jig.
Important:
• The following USB storage devices are recommended for updating.
- MELCO ClipDrive
(RUF-C128M)
- Lexar Media
JumpDrive (RD128-231)
- Iomega
Mini USB Drive (Mini 128MB USB Drive)
• Only the USB storage device which meets the following conditions should be used for updat-
ing. Be careful since updating with any device other than the above is never guaranteed.
- A combination USB storage device with a flash memory (to be connected directly to the
USB port) and its capacity is 64 MB or more
- A USB storage device which is complied with the following standards regulated by USB-IF
(USB Implementers Forum)
Class number:
8 (=08h) (Mass-storage class)
Sub-class number:
6 (=06h) (SCSI transfer command set)
Protocol number:
80 (=50h) (Bulk-Only)
* Most common USB storage devices are complied with the specification above and can
be used for updating. However, the operation in this equipment is not always
guaranteed since the most of these devices are developed based on the use in PC
environ ment (Windows or Macintosh). Therefore, confirm thoroughly that the device is
opera tional in this equipment when purchasing the device.
• The USB storage device complied with USB1.1 and USB2.0 can be used for updating. How-
ever, the update is performed in the speed of USB1.1 when the device complied with USB2.0
is used.
• Do not update the firmware by any storage device other than a flash memory (such as a USB
connection type memory card reader, CD/DVD drive or hard disk) since it is never guaran-
teed.
Firmware
Stored
Date file name
Master data
Hard disk
1, 2, 3... n
*
The file name should be consecutive numbers from
1 to “n” without file extension. The capacity of each
file is approx. 8 MB. However, the file capacity of “n”
(last number) may be less than 8 MB.
System ROM
System control PC
board (SYS board)
sysfirm.bin, ROM.bin
Engine ROM
Logic PC board (LGC
board)
ROM.bin
Scanner ROM
Scanning section con-
trol PC board (SLG
board)
NIC ROM
NIC board