e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
FIRMWARE UPDATING
6 - 84
If the updating of the NIC firmware is still failed, check the prescription corresponding to the error
message. After confirming and clearing the problem, restart updating from the beginning.
Note:
Note:
If the updating of the NIC firmware is not completed properly, wait 5 minutes or more from the
beginning of the updating before turning OFF the power, and then restart updating from the
beginning. If you turn OFF the power within 5 minutes, HDD may be destroyed.
(9) Turn OFF the power, remove the USB storage device and install the connector cover.
(10) Perform the initialization of the updating data (NVRAM updating).
a. Turn ON the power while [0] button and [8] button are pressed simultaneously.
b. Key in “947”, and then press the [START] button.
c. Press the [INITIALIZE] button.
NIC Error Message
Error Contents
Prescription
NIC UPDATE FAILED 1
NIC initialization time-out
The IP address may not be assigned cor-
rectly.
•
Is the IP address assigned correctly?
•
Does the IP address conflict with the
other system?
If the error still occurs, replace the NIC
board because it may be destroyed.
NIC UPDATE FAILED 2
ATA driver initialization error The HDD cable may be disconnected.
•
Is the HDD cable connected correctly?
If the HDD cable is connected correctly,
replace the SYS board because it may be
destroyed.
NIC UPDATE FAILED 3
HDD partition mount error
Replace the HDD because it may be
destroyed.
NIC UPDATE FAILED 4
NIC setting information
backup error
Replace the HDD because it may be
destroyed.
NIC UPDATE FAILED 5
NIC firmware transfer error
Replace the NIC board because it may be
destroyed.
NIC UPDATE FAILED 6
NIC firmware writing error
Replace the NIC board because it may be
destroyed.
NIC UPDATE FAILED 7
NIC status time-out
Replace the NIC board because it may be
destroyed.
NIC error message