e-STUDIO350/352/353/450/452/453
FIRMWARE UPDATING
6 - 93
6
Update program
The firmware can be updated to the latest version without considering the current one by storing the
update program together with the firmware data file for updating in the USB Storage Device.
Fig. 6-69
Important:
• The "mentusb.o" file stored in the root of the USB storage device is a common file in e-
STUDIO850 Series, e-STUDIO451c Series and e-STUDIO282 Series. To save the firmware
of more than one model into one USB storage device, one "mentusb.o" file stored in the root
of USB storage device is sufficient.
• Be careful not to mix up the "mentusb.o" file because there is a file whose name is the same
in the localization tool.
Name
File name
Stored
Tool object for updating
mentusb.o
root
Update program
dlFirmWare_352_452
[352_452] folder
(Model specific folder)
USB Storage Device
352_452
dlFirmWare_352_452
firmImage0.bin
1
3
:
2
firmImage1.bin
firmImage2.bin
mentusb.o
07/05