e-STUDIO350/352/353/450/452/453
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
REMOTE SERVICE
8 - 4
8.1.3
Setting procedure
(1) Start up the self-diagnosis setting mode 08-765, and then change the setting value to "0".
(2) Turn the power OFF, and then ON.
(3) Press the [USER FUNCTIONS] button to enter the user function screen.
(4) Press the [ADMIN] button.
• When the Administrator Password has been set, ADMINISTRATOR PASSWORD screen is
displayed.
(5) Press the [PASSWORD] button and the screen is switched to a full keyboard. Then key in the
Administrator Password and press the [ENTER] button.
* Confirm the password to the administrator.
(6) Press the [SERVICE] button in the ADMIN screen.
05/05