December 2002 TOSHIBA TEC
1 - 53
e-STUDIO160/200/250 ADJUSTMENT ITEMS
1.3 Image Quality Control
If the user wants to change the image density, adjust the image density in adjust mode "05."
Follow the procedure below to adjust the image density to suit the user’s preferences while comparing the
image obtained in the test copy and the currently entered allowable values.
<Keys used in operation>
Notes:
1. Adjustment value is able to be input within the range of 0 - 255.
2. Default values are as following.
Code
Default value
501
139
503
133
504
130
505
28
506
18
507
20
508
13
509
20
510
18
512
140
514
133
515
130
Original mode
Adjustment item
Remarks
Photo/Text
Photo
Text
503
501
504
Standard PPC Manual density
The larger the value, the darker
center value
the image
505
506
507
Light side
Manual density
The larger the value, the lighter
the light range
508
509
510
Dark side
Manual density
The larger the value, the darker
the dark range
514
512
515
Standard PPC Automatic density The larger the value, the darker
the image
Code
Power ON
0
5
Digital Keys
SET
Digital Keys
SET
INT
START
INT
Power OFF
(Code)
(Set the value)
(Test print)
or
START
or
START