e-STUDIO167/207/237
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 26
[J]
CIS unit drive belt-2
(3)
Take off the CIS unit drive belt-1.
Note:
When assembling the CIS unit drive belt-1,
assemble it while the fixing screw is loos-
ened. Then tighten the fixing screw of the
tension bracket.
Fig. 6-36
(1)
Take off the scanner top cover.
"
P.6-18 "[B] Scanner top cover"
(2)
Take off the right rear cover.
"
P.2-22 "[I] Right rear cover"
(3)
Take off the CIS unit drive belt-1.
"
P.6-25 "[I] CIS unit drive belt-1"
(4)
Loosen 2 fixing screws of the scan motor.
Fig. 6-37
(5)
Take off the CIS unit drive belt-2.
Note:
When assembling the CIS unit drive belt-2,
be sure to perform the tension adjustment for
the scan motor.
"
P.6-20 "[D] Scan motor (M1)"
Fig. 6-38
CIS unit drive belt-1
Scan motor
CIS unit drive belt-2