e-STUDIO182/212/242
SCANNER
6 - 17
6.7.2
Scanner top cover
Notes:
1. Install the ADF original glass so that the
attached Mylar sheet is placed on the
front side.
2. When installing the ADF original glass,
place it between 2 small guides with its
left-hand side pushed to the scanner top
cover.
Fig. 6-14
(1) Take off the original glass.
P.6-16 "6.7.1 Original glass"
(2) Take off the front upper cover.
P.2-19 "2.5.6 Front upper cover"
(3) Take off the control panel unit.
P.5-7 "5.5.1 Control panel unit"
(4) Remove 8 screws and take off the scanner
top cover.
Fig. 6-15
Guide
Guide
Mylar
Scanner top cover