e-STUDIO182/212/242
© 2009 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 18
6.7.3
Automatic original detection sensor (APS sensor)
[C-1] A4 series (S9-S13)
[C-2] LT series (S10-S13)
6.7.4
Scan motor (M1)
(1) Take off the original glass.
P.6-16 "6.7.1 Original glass"
(2) Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 5 APS
sensors.
Note:
When installing the automatic original
detection sensor, connect the connector
(yellow) to the connect one.
Fig. 6-16
(1) Take off the original glass.
P.6-16 "6.7.1 Original glass"
(2) Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 4 APS
sensors.
Note:
When installing the automatic original
detection sensor, connect the connector
(yellow) to the connect one.
Fig. 6-17
(1) Take off the scanner top cover.
P.6-17 "6.7.2 Scanner top cover"
(2) Disconnect 1 connector.
Fig. 6-18
Sensor
Connector (Yellow)
Connector
Sensor
Connector
Connector (Yellow)
Connector
Summary of Contents for e-studio182