e-STUDIO182/212/242
© 2009 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 20
6.7.5
CIS home position sensor (S1)
6.7.6
Platen sensor (S2)
(1) Take off the original glass.
P.6-16 "6.7.1 Original glass"
(2) Remove 1 screw and take off the CIS home
position sensor with the bracket.
Fig. 6-22
(3) Release 2 latches, take off the CIS home
position sensor, release the harness from
harness clamp and disconnect 1 connector.
Fig. 6-23
(1) Take off the scanner top cover.
P.6-17 "6.7.2 Scanner top cover"
(2) Remove 1 screw and take off the sensor with
the bracket.
(3) Disconnect 1 harness clamp and 1
connector.
Fig. 6-24
Bracket
CIS home position sensor
CIS home position sensor
Connector
Bracket
Connector