9.5.10
Damp heater unit (DH3) / Dummy plate
Notes:
• This damp heater unit is optional for NAD, CND and MJD.
• The dummy plate is attached to the equipment in which the damp heater unit is not installed.
To take it off, perform the procedure from step (3).
9.5.11
Paper empty sensor (S7)
(1) Take off the rear cover.
P.2-21 "2.5.10 Rear cover"
(2) Release the harness from the harness clamp
and disconnect the connector.
Fig. 9-31
(3) Take off the process unit.
P.10-9 "10.7.1 Process unit"
(4) Remove 1 screw and take off the damp
heater unit or dummy plate while sliding it to
the rear side and lifting it up.
Fig. 9-32
(1) Take off the drawer.
(2) Take off the damp heater unit or dummy
plate.
P.9-18 "9.5.10 Damp heater unit (DH3) /
Dummy plate"
(3) Disconnect 1 connector, remove 1 screw,
and take off the bracket of the paper empty
sensor.
Fig. 9-33
Connector
Damp heater unit or
dummy plate
Screw
Connector
Bracket
Summary of Contents for e-studio182
Page 12: ......
Page 18: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 6 ...
Page 76: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved COPY PROCESS 3 14 ...
Page 120: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved SCANNER 6 26 ...
Page 128: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved LASER OPTICAL UNIT 7 8 ...
Page 228: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved FUSER EXIT UNIT 12 24 ...
Page 257: ......
Page 258: ......