10
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO182/212/242
DRUM RELATED SECTION
10 - 11
10.7.2
Drum cleaner unit
(1) Take out the process unit.
P.10-9 "10.7.1 Process unit"
(2) Disconnect 2 connectors and remove 2
screws.
(3) Release 1 latch. Then pull out the process
unit front cover and take it off.
Note:
When installing the process unit front cover,
wire the harness correctly in order not to
contact the gears and harness of the process
unit front cover each other.
Fig. 10-10
Fig. 10-11
Fig. 10-12
Process unit front cover
Connector
Connector
Latch
for MJD
Process unit front cover
Connector
Connector
Latch
except for MJD
Process unit
front cover
Harness