e-STUDIO182/212/242
© 2009 TOSHIBA TEC CORPORATION All rights reserved
DRUM RELATED SECTION
10 - 14
10.7.6
Main charger cleaner
10.7.7
Needle electrode
(1) Take off the main charger.
P.10-13 "10.7.4 Main charger"
(2) Release the hook of the cleaning shaft. Then
rotate the shaft at 90 degrees to take it off.
Fig. 10-19
(1) Take off the main charger grid and main
charger cleaner.
P.10-13 "10.7.5 Main charger grid"
P.10-14 "10.7.6 Main charger cleaner"
(2) Take off the terminal covers of both front and
rear sides.
Fig. 10-20
(3) Remove the terminal and spring. Then take
off the needle electrode.
Notes:
1. Do not touch the needle electrode directly
with bare hands.
2. Make sure not to hold or bend the needle
electrode.
Fig. 10-21
Main charger cleaner
Terminal cover
Needle electrode
Terminal
Spring