e-STUDIO182/212/242
© 2009 TOSHIBA TEC CORPORATION All rights reserved
DRUM RELATED SECTION
10 - 16
10.7.11 Recovery blade
10.7.12 Transfer/Separation charger
(3) Take off the drum separation finger with the
spring.
Note:
When the drum separation fingers have been
replaced, check if the pressure movement is
normal by moving them with your hands.
Fig. 10-25
(1) Take off 2 drum separation finger units.
P.10-15 "10.7.10 Drum separation finger"
(2) Remove 2 screws, and take off the whole
recovery blade with the bracket.
Fig. 10-26
(1) Open the ADU cover and transfer unit.
(2) Release the latch and take off the transfer
and separation chargers.
Fig. 10-27
Drum separation finger
Spring
Recovery blade
Transfer/ Separation charger
Summary of Contents for e-studio182