12
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO182/212/242
FUSER / EXIT UNIT
12 - 11
7. Abnormality detection by the thermistors
The following table shows the conditions judging the fuser roller temperature abnormality and
detecting timing.
* The figures in the “priority” section denote the priority of error checking.
Checking
timing
Priority
Temperature judged
Error-
judging
timing
Error
code
Center
thermistor
Side
thermistor
Edge
thermistor
On usual
1
230°C or above
-
-
On usual
C44
-
230°C or above
-
-
-
230°C or above
Detecting 40°C
1
40°C or below
-
-
Specified
time
C41
-
40°C or below
-
Detecting 100°C
1
100°C or below
-
-
Specified
time
C44
-
100°C or below
-
2
40°C or below
150°C or above
-
On usual
C43
150°C or above
40°C or below
-
Detecting
warming-up
temperature
1
Warming-up temp.
or below
-
-
Specified
time
C44
-
Warming-up temp.
or below
-
2
40°C or below
150°C or above
-
On usual
C43
150°C or above
40°C or below
-
-
150°C or above
40°C or below
During ready
status
1
40°C or below
150°C or above
-
On usual
C43
150°C or above
40°C or below
-
-
150°C or above
40°C or below
2
40°C or below
-
-
C44
-
40°C or below
-
During copying
1
40°C or below
-
-
On usual
C44
-
40°C or below
-
2
-
-
40°C or below
C45
Summary of Contents for e-studio182
Page 12: ......
Page 18: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 6 ...
Page 76: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved COPY PROCESS 3 14 ...
Page 120: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved SCANNER 6 26 ...
Page 128: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved LASER OPTICAL UNIT 7 8 ...
Page 228: ...e STUDIO182 212 242 2009 TOSHIBA TEC CORPORATION All rights reserved FUSER EXIT UNIT 12 24 ...
Page 257: ......
Page 258: ......