2.Copier-specific Adjustments
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
2-86
Full
color
05-7690
-
Color
reproduction
selection
0 to 6
0
0: Same as Text/Photo,
printed image, text, map
(text priority) mode
1: Same as Photo mode
2: Same as Red seal color
mode
3: The gray level becomes a
more bluish one than the
one specified in the setting
value “0”.
4: The highlight
reproduction becomes more
emphasized than the one
specified in the setting
value “0”.
5: Same as Text/Photo,
printed image, text, map
(photo priority) mode
6: Text/Photo, printed
image, text, map mode
(equivalent to the setting
value “0” of the base model
(*1): reproduction which
enhances the redness of
skin)
(*1): e-STUDIO2000AC/
2505AC/3505AC/4505AC/
5005AC
05-7718
-
Density
adjustment
(Manual
adjustment
(Center value))
0 to 255
128
The larger the value, the
darker the image becomes.
05-7725
-
Density
adjustment
(Automatic
density
adjustment)
0 to 255
128
The larger the value, the
darker the image becomes.
05-7795
-
Sharpness
adjustment
0 to 255
128
The larger the value, the
sharper the image
becomes. The smaller the
value, the softer the image
becomes and the less moire
appears.
05-7816
-
Black header
density level
adjustment
0 to 8
0
The larger the value, the
darker the header becomes.
The smaller the value, the
lighter the header becomes.
Color
mode
[05] Code
Sub
code
Adjustment
Acceptable
value range
Default
Setting value
Reference
section