2.Copier-specific Adjustments
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
2-91
(1) Press [Edit] tab on the Copy mode and then press [Omit Blank Page].
Then press [OK] to enable the Omit Blank Page function.
After the setting, copy and check the image.
If there is any page other than colored pages that cannot be omitted, perform the procedure below.
(2) Press [User Functions -User-] on the [Home] screen. Then press [+] or [-] of [Omit Blank Page
Adjustment].
• When moving the slide bar to the right by pressing [+], the scanned originals tend to be detected
as blank pages.
(3) Select [05 ADJUSTMENT MODE]. Change the value for the code [7618] to adjust the threshold for
judging the original as blank pages.
• The larger the setting value is, the more the original tends to be judged as a blank page.
• Set the value in increments of approximately 15 until the optimum value is obtained, while
checking if proper originals are judged as a blank page.
(4) Select [05 ADJUSTMENT MODE] and change the setting value for the code [7616] to adjust the
image area on the edge of the original to be used for the judgment for “Omit Blank Page”.
• If the judgment of an original whose image is located only on the edge of the paper has not been
carried out as desired, arrange the threshold by setting a smaller value in order to make the
judgment area wider.
• Adjust the code which corresponds to the Image Repeat setting.
• The setting values of 24 steps correspond to 1 mm of the image area.
• If too small a value is set, shadows or stains on the edge of the original may be judged as images
and thus the desired result may not be obtained.
Caution after the adjustment
• When the threshold for judging blank pages is changed, the same threshold for in the network
scanning function is also changed.
• Note that arranging the image area to be used for the judgment also adjusts that for “Omit Blank Page”
in network scanning.
• Originals with a small portion of small letters may be judged as a blank page. Therefore adjust the
value carefully while checking the copy image.
[05] code
Recommended value
Acceptable range value
Default
05-7618
Set a value larger than 128.
0 to 255
128
Items
[05] Code Subcode
Recommended
value
Acceptable
value range
Default
When Image Repeat is
not used
05-7616
0
Set a value smaller
than 200.
0 to 255
200
When Image Repeat is
used
2