2.Copier-specific Adjustments
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
2-93
(1) Press [Basic] tab on the Copy mode and press [
] to lower the copy density manually.
After the adjustment is complete, make a copy and confirm the image quality. If uneven image
density still persists, have the service technicians perform the following procedure.
(2) Select [05 ADJUSTMENT MODE]. Change the setting values for codes [7237], [7286] and [7287] to
set the range correction to be fixed.
• Description of the setting value
After the adjustment is complete, make a copy and confirm the image quality.
Caution after the adjustment
Nothing in particular
Color mode
Original mode
[05]code
Recommended
value
Acceptable value
range
Default
Black
Text/Photo
05-7286
0
0, 1
0
Text
05-7287
1
User Custom
05-7237
1
Value
Range correction
0
Fixed
1
Flexible