Self-diagnosis code
Caution after the adjustment
Nothing in particular
Resolution Halftone
Color
mode
[05]code
Subcode
Recommended
value
Acceptable
value range
Default
600 dpi
Smooth
Color
05-8010
0/1/2
Set a value larger
than 128.
0 to 255
128
Twin
color
05-8011
Mono
color
05-8012
Detail
Color
05-8013
Twin
color
05-8014
Mono
color
05-8015
1200 dpi
Smooth
Color
05-8016
-
Mono
color
05-8018
Detail
Color
05-8017
Mono
color
05-8019
Subcode
PDL
0
PS
1
PCL
2
XPS