1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
1-21
To optimize the image quality stability according to the number of output pages in a day or
the type of originals:
By changing the setting value for [08] codes, the image quality control can be started at the desired
timing after the specified number of pages have been output. Referring to the guide below, set the
value appropriately in accordance with the total number of pages output in a day, the number of jobs
frequently performed, or the requested image quality in the user’s office.
After changing the setting value, perform the image quality control following the procedure below.
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
After performing the adjustment, print the image and check its quality.
*7.To start the Short Mode at every 30 pages, set the value to “30” for both 08-2497 and 08-9199.
However, setting a too-short interval will use up too much toner, even though the consumption in
the Short Mode is approximately a quarter of that in the Full Mode.
(A). For standard office use (mainly business documents) (Default)
Code to set
number of
pages
Setting value
Starting conditions
Full IQC
08-2509
1000
The control starts after every 1000 pages.
Short IQC
08-2497
100
The control starts after 50 pages have been
output, or when a job is interrupted after every
500 pages.
Printing
interrupted
08-9199
500:
e-STUDIO2010AC/
2510AC
400:
e-STUDIO2515AC/
3015AC/3515AC/
4515AC/5015AC
(B). To stabilize the density in continuous copying/printing (when interrupting jobs and starting the
Short Mode at every 50 pages)
Code to set
number of
pages
Setting
value *7
Starting conditions
Full IQC
08-2509
1000
The control starts after every 1000 pages.
Short IQC
08-2497
50
The control starts when a job is interrupted after every
50 pages.
Printing
interrupted
08-9199
50
Summary of Contents for e-STUDIO2010AC
Page 1: ...File No SME18003400 R180821V5800 TTEC Ver00F_2018 10 ...
Page 6: ...Revision Record Ver00 2018 10 19 Page Contents All Initial release ...
Page 339: ......