1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
© 2018 TOSHIBA TEC CORPORATION All rights reserved
1-36
e-STUDIO2010AC/2510AC
Adjustment method
Tilting the developer unit.
Adjustment procedure
(1) Remove the waste toner box, toner cartridge, developer unit, cleaner unit, left cover and receiving
tray from the MFP.
Refer to the following pages of the Service Manual
(a) 4.6.1 Waste toner box
(b) 4.6.2 Developer unit
(c) 4.6.10 Cleaner unit
(d) 4.1.2 Left cover
(e) 4.1.3 Receiving tray
(2) Remove 3 screws [1].
(3) Release the latches [1], and then take off the toner
cover [2].
<Note>
• When taking off the toner cover, remove the cooling duct
[3], and toner stays [4] and [5].
(4) Loosen 5 screws [1].
(5) Move the frame [2] to the right or left to adjust its
position.
Remark:
• Up to 1 mm is adjustable (0.5 mm for the right and left).