1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
© 2018 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
1-39
(5) Temporarily tighten the screw [9] removed in step (4)
into the screw hole [3].
(6) Select the closest value to the tilted volume “A-B” from the following table and check the scales of
the frame and the LSU holder to be aligned.
Scale position to be aligned
Tilted volume (A-B): [Unit: mm]
Frame
LSU holder
297 mm (A3)
279 mm (LD)
Front
Eighth
Eighth
1.12
1.04
Seventh
Seventh
0.98
0.91
Sixth
Sixth
0.84
0.78
Fifth
Fifth
0.7
0.65
Fourth
Fourth
0.56
0.52
Third
Third
0.42
0.39
Second
Second
0.28
0.26
First
First
0.14
0.13
Center
0
0
0
0
Rear
First
First
-0.14
-0.13
Second
Second
-0.28
-0.26
Third
Third
-0.42
-0.39
Fourth
Fourth
-0.56
-0.52
Fifth
Fifth
-0.7
-0.65
Sixth
Sixth
-0.84
-0.78
Seventh
Seventh
-0.98
-0.91
Eighth
Eighth
-1.12
-1.04
Remarks
Moving approx.
0.14 mm per 1
scale
Moving approx.
0.13 mm per 1
scale
Summary of Contents for e-STUDIO2010AC