2 SETTING ITEMS (ADMIN)
214 IEEE 802.1X Authentication Setting
Error messages
The following error messages may be displayed on the touch panel.
Message
Cause
[802.1X] Auth Server/Switch couldn’t be contacted
y
The RADIUS server service is stopped.
y
Configuration for the RADIUS server is not correct.
y
The IEEE 802.1X switch has problem.
[802.1X] Authentication failed
y
The username or password that the user entered is not
correct.
y
The certificates uploaded are wrong.
Certificate verification Failure
y
A CA certificate is not installed in the equipment.
y
The installed CA certificate is not valid.
y
The server certificate is invalid.