e-STUDIO550/650/810 TROUBLE SHOOTING
5 - 36
JUNE 2002 © TOSHIBA TEC
[E80] Jam access cover opened during original feeding
[E81] Jam access cover opened during original transporting
[E82] Jam access cover opened during large-sized original discharging
[E83] Jam access cover opened during small-sized original reversing
[E84] Jam access cover opened during small-sized original discharging
[E85] Jam access cover opened at the scanning section
Are the connector CN3 and CN12 on the ADF board disconnected?
Connect the connector.
Is the harness between the ADF board and cover open/close sensor open-circuited?
Replace the harness.
Is the cover open/close sensor working improperly?
Replace the cover open/close sensor.
Is the harness between the ADF board and cover open/close sensor open-circuited?
Replace the harness.
Is the cover open/close sensor working improperly?
Replace the cover open/close sensor.
Is the harness between the ADF board and RADF open/close switch open-circuited?
Replace the harness.
Is the RADF open/close switch working improperly?
Replace the RADF open/close switch.
Is 24V supplied from the copier?
1. Replace the ADF board.
2. Perform the EEPROM initialization of RADF, sensor automatical adjustment
and tray volume adjustment.
Check if the power at the copier is ON.
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
YES
NO