e-STUDIO550/650/810 ADJUSTMENT
3 - 14
June 2002 © TOSHIBA TEC
(c) Image position adjustment of the primary scanning direction (Deviation adjustment of the scanner
primary scanning start position)
1. Turn ON the power while the digital keys [0] and [5] are pressed simultaneously.
(Adjustment
mode)
2. Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
3. Select the condition of 2nd cassette (A3/LD) and 100% and press the [COPY] key to make a copy.
4. Measure the distance B from the left edge of the paper to 100 mm of the copied image of the ruler.
5. Check if the distance B is within the range of 100±1.0 mm .
6. If not, change the value taking the following procedure, and repeat the steps 3 to 5 until the distance
falls within range.
<Procedure>
(Adjustment mode)
(Enter the code [306] with the digital keys)
[START]
(Enter a value (acceptable values : 0 to 255) with the digital keys)
Press the [SET] or the [INTERRUPT] key to store the value in the RAM.
(“100% A” is displayed.)
* The larger the adjustment value, the more the image is shifted to the right and the
distance B becomes wider (0.0423 mm/step).
Copied image of the ruler
Feeding direction
50
100
150
200
B