e-STUDIO550/650/810 ADJUSTMENT
3 - 20
June 2002 © TOSHIBA TEC
Original mode
Items to adjust
Remarks
Text/Photo
Photo
Text
Code
620
621
622
Sharpness setting
Enter one of the following values in the original mode.
Units:
1: Text/Photo 2: Photo
5: Text
Tens:
0: Use default value
1~9: Change intensity
(The larger the value, the sharper the image
becomes.)
• Example of value entry in case the original
mode is “Text/Photo”.
2
1
Fixed value for Text/Photo mode
Enter a value 0 to 9
Note: When the value “0” is entered in the
tens digit, the value is not displayed on
the LCD screen.
3. 4. 2. Sharpness adjustment for copier
When making the image sharpness softer or harder, adjust the sharpness setting in the adjustment
mode “05”.
The entry procedure of the adjustment value is the same as that for “3.4.1 Image density”.
3. 4. 3. Gamma slope adjustment
If the user requests to change the gamma slope, perform the gamma slope adjustment in the adjustment
mode “05”.
The entry procedure of the adjustment value is the same as that for “3.4.1 Image density”.
Original mode
Items to adjust
Remarks
Text/Photo
Photo
Text
Code
593
594
595
Gamma slope adjustment
0: Use default value (equivalent to the set
value 5)
1 to 9: Gamma data (The larger the value, the
darker the image becomes)