January 2000 © TOSHIBA TEC
1 - 63
FC-22 ADJUSTMENT
3. Press [ENERGY SAVER]
촞
[START] to make a copy in the mode of A4 (LT), 100%, full color and text/
photo.
4. Measure the distance E from the upper paper edge to the upper mark (10 mm) on the copy with a
ruler.
5. Check if the distance E is within a range of 10±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat the steps 3. to 5. above.
<Procedure>
(Adjustment mode)
촞
(Input code [105] with digital keys)
촞
[START]
촞
(Input a value
(acceptable values : 128 to 135) with digital keys)
촞
[INTERRUPT] (Stored in memory)
* The larger the adjustment value, the longer the distance E becomes (0.12 mm/step).
(h) Right margin (Printed page right edge void adjustment)
1. While pressing the digital keys [0] and [5] simultaneously, turn the power ON.
촞
(Adjustment mode)
2. Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).
3. Press [ENERGY SAVER]
촞
[START] to make a copy in the mode of A4 (LT), 100%, full color and text/
photo.
4. Measure the blank area F to the right of the copy image with a ruler.
5. Check if the blank area F is within a range of 2±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat the steps 3. to 5. above.
<Procedure>
(Adjustment mode)
촞
(Input code [427] with digital keys)
촞
[START]
촞
(Input a value
(acceptable values : 0 to 255) with digital keys)
촞
[INTERRUPT] (Stored in memory)
* The larger the adjustment value, the larger the blank area becomes (0.042 mm/step).
(i) Bottom margin (Printed page trailing edge void adjustment)
1. While pressing the digital keys [0] and [5] simultaneously, turn the power ON.
촞
(Adjustment mode)
2. Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).
3. Press [ENERGY SAVER]
촞
[START] to make a copy in the mode of A4 (LT), 100%, full color and text/
photo.
4. Measure the blank area G beneath the copy image with a ruler.
5. Check if the blank area G is within a range of 2.5±0.5 mm or not.
6. If it is not, change values using the following procedure, and repeat the steps 2 to 4 above.
<Procedure>
(Adjustment mode)
촞
(Input code [428] with digital keys)
촞
[START]
촞
(Input a value
(acceptable values : 0 to 255) with digital keys)
촞
[INTERRUPT] (Stored in memory)
* The larger the adjustment value, the larger the blank area becomes (0.042 mm/step).
Summary of Contents for FC22
Page 115: ...FC 22 PREVENTIVE MAINTENANCE 2 8 January 2000 TOSHIBA TEC Front side drive system 47 20 ...
Page 121: ......
Page 235: ...January 2000 TOSHIBA TEC 5 29 FC 22 FIRMWARE UPDATING ...
Page 237: ...FC 22 SERVICE HANDBOOK 6 WIRE HARNESS CONNECTION DIAGRAMS 6 2 DC Wire Harness ...
Page 238: ...FC 22 WIREHARNESS CONNECTION DIAGRAMS 6 3 January 20000 TOSHIBA TEC ...