3
ALIGNMENT PROCEDURE
Base Unit
Transmitter Section
Connections
Preset
a) Connect the base RF unit to the base main unit.
b) Set the “TONE / PULSE” switch to PULSE.
c) Connect the AC adapter to the base unit while pressing the “PAGE” key, and keep pressing it continuously for
approximate 2 sectonds.
d) Release the “PAGE” key when entering TEST mode 1 with IN USE LED lighting.
Alignment Procedure
Alignment Point Location on Base Main PCB and Base RF PCB
step
1
2
3
Adjustment
RT301
(TX Power)
CT1
(TX Frequency)
RT3
(TX Modulation)
Remarks
Connect the Power Meter to the RF test point on the Base MAIN PCB.
Adjust RT301 for a -6.5dBm reading on the Power Meter.
Connect the Frequency Counter to the RF test point on the Base MAIN
PCB. Adjust CT1 to make sure that the frequency is 926.897468 MHz.
Press the “PAGE” key to enter the TEST Mode 2. Connect the AF Generator
to the TEL Line Jack on the Base Main PCB. Make sure that the output is 1
kHz 138 mV from the AF Generator.
Connect the Deviation Meter to the RF test point on the Base MAIN PCB.
Adjust RT3 to indicate ±8 kHz Dev.
Power
Meter
RF
Test Point
BASE Unit
J2
DC IN
9V Jack
1kHz 138mV
AF GEN.
AC 120V
60Hz
Frequency
Counter
Deviation
Mater
RF
Test Point
J1
TEL Line
Jack
AC
Adapter
S2
T/P Switch
P
T
RF Test Point
J2
DC IN 9V Jack
J1
TEL LINE Jack
Base Main PCB
RT3
RT301
CT1
Base RF PCB
Summary of Contents for FT 8000
Page 1: ...CORDLESS TELEPHONE PUBLISHED IN JAPAN Aug 2000 SERVICE MANUAL FILE NO 2B0 200006 FT 8000 ...
Page 10: ...9 10 SCHEMATIC DIAGRAMS Base Unit ...
Page 11: ...11 12 Handset ...
Page 25: ...26 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 26: ...27 Handset Main PCB ...
Page 27: ...28 WIRING DIAGRAMS Base Unit ...
Page 28: ...29 Handset ...
Page 47: ......