6
Receiver Section
Connections
Alignment Point Location on Handset Main PCB and Handset RF PCB
Preset
a) Connect the handset RF unit to the handset main unit.
b) Connect DC power supply to battery connector on the handset unit.
c) Turn the DC power supply ON while pressing “
∗
” and “ # ” keys, and keep pressing the keys continuously for
approximate 2 seconds.
d) Release keys when entering TEST mode 1 with TALK LED lighting and beep.
Alignment Procedure
step
1
2
3
Preset to
SG: 1mV
No modulation
SG: 1mV
1 kHz ±8kHz
deviation
SG: -6.0 dB
µµµµµ
V
1kHz ±8kHz
Deviation
Remarks
Press the “4” key to enter the TEST Mode 4. Connect the RF Singal
Generator to the RF test point on the handset MAIN PCB. Make sure that
the frequency is 926.997467 MHz.
Connect the DC Voltmeter to the AF Terminal of RT601. Adjust L602 to
indicate DC 0.85 V.
Connect the RF Signal Generator to the RF test point on the handset MAIN
PCB. Make sure that the frequency is 926.997467 MHz.
Connect the AC Voltmeter across a 150-ohm dummy to the SP Connector.
Adjust RT602 for a 247 mV reading on the AC Voltmeter.
Press the “5” key to enter the TEST Mode 5. Make sure that the frequency
of RF SG output is 926.997467 MHz. Adjust RT601 to turn to the point
where the indication is just vibrated.
Adjustment
L602
(Discriminator
Voltage)
RT602
(RX AF
Voltage)
RT601
(SQ Point)
AC Voltmeter
HANDSET Unit
AF Terminal
of RT601
Dummy Load
(150-ohm)
RF SG
DC 3.8V
J601
Battery
Connector
+
RF
Test Point
SP
Connector
DC Power Supply
DC Voltmeter
-
+
-
RF Test Point
RT601
RT602
J601
RF PCB
Handset PCB
L602
AF Terminal
Summary of Contents for FT 8000
Page 1: ...CORDLESS TELEPHONE PUBLISHED IN JAPAN Aug 2000 SERVICE MANUAL FILE NO 2B0 200006 FT 8000 ...
Page 10: ...9 10 SCHEMATIC DIAGRAMS Base Unit ...
Page 11: ...11 12 Handset ...
Page 25: ...26 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 26: ...27 Handset Main PCB ...
Page 27: ...28 WIRING DIAGRAMS Base Unit ...
Page 28: ...29 Handset ...
Page 47: ......