25
10.
10.
10.
10. Parameter Register
Parameter Register
Parameter Register
Parameter Register Access
Access
Access
Access
10.1
10.1
10.1
10.1 Parameter Number / Action Output Words
Parameter Number / Action Output Words
Parameter Number / Action Output Words
Parameter Number / Action Output Words
To access inverter parameters, 2 output words are provided in the output data
structure. The structure of these 2 output words is as follows:
Parameter number / action word
Bit #:
15 14 13 12 11
8 7
4 3
0
Reser
v
ed
Reser
v
ed
Req1
Req0
Parameter number / action
high byte (offset 4)
Parameter number
low byte (offset 5)
Parameter data write word
Bit #:
15 12
11 8
7
4
3
0
Parameter data to write
high byte (offset 6)
Parameter data to write
low byte (offset 7)
Parameter number (12 bits)
Parameter data (16 bits)