44
Register
Function / Title
Bank
Mask
Adjustment Range
Multiplier
135
UNDERVOLTAGE TRIP
SELECTION
0 / 1
0080
0000: Trip disabled
(0)
0080: Trip (during run)
(1)
136
UNDERVOLTAGE DETECT
TIME
0 / 1
FFFF
0000
∼
03E8 (0.00
∼
10.00)
0.01
137
LOW CURRENT DETECT
SELECTION
0 / 1
0008
0000: Trip disabled
(0)
0008: Trip on detection
(1)
138
LOW CURRENT DETECT
LEVEL
0 / 1
00FF
0000
∼
0064 (0
∼
100)
1
139
LOW CURRENT DETECTION
TIME
0 / 1
00FF
0000
∼
00FF (0
∼
255)
1
140
OUTPUT SHORT-CIRCUIT
DETECTION SELECT
0 / 1
0003
0000: Standard motor
(0)
0001: High-speed motor
(1)
0002: Positioning use (standard
motor) (2)
0003: Positioning use (high-speed
motor) (3)
141
OVERTORQUE TRIP
SELECTION
0 / 1
0040
0000: Trip disabled
(0)
0040: Trip enabled
(1)
142
OVERTORQUE TRIP LEVEL
0 / 1
00FF
0000
∼
00C8 (0
∼
200)
1
143
FAULT TRIP EEPROM
SAVE ENABLE
0 / 1
0002
0000: Data cleared when powered
OFF (0)
0002: Data retained when powered
OFF (1)
144
COOLING FAN CONTROL
SELECTION
0 / 1
0004
0000: Automatic (temperature
detection) (0)
0004: Always ON
(1)
145
CUMULATIVE RUN TIMER
ALARM SETTING
0 / 1
FFFF
0000
∼
C34B (0.00
∼
999.90)
0.02