3-28
3
Service Procedures
8.
When the message “Copy software to parallel port” appears on the Control Panel, return
to the PC and type the following command at the MS-DOS prompt:
copy System.efi lpt1 /b
System.efi
refers to the system file on the System Software CD and
/b
specifies the binary
option (not ASCII). Make sure to spell the filename correctly and include the file
extension.
9.
Press the Enter key on the PC. Then press the Set button on the Control Panel.
Wait while the GA-1121 Control Panel displays status messages indicating that the
GA-1121 is receiving the file and installing the system software. Do not press any keys
during this time. This process takes approximately 15 minutes and can take much longer
depending on your PC.
10.
When the message “Installation was successful” appears on the Control Panel, press the
Set button.
The Config Mode screen appears.
11.
Select the Resume Boot option and press the Set button.
Once the system boots up, the language screen will appear on the Control Panel.
12.
Select the language you want to use.
13.
At the Setup screen, select Run Setup and press the Set button. Reenter the customer’s
settings from the Configuration page that you printed earlier.
Enter settings for Server, Network, and Printer Setup, in that order. Ignore the settings
not included on the Configuration page if it is more appropriate for the network
administrator to set them. See the GA-1121 user documentation for more information.
14.
After all setup options are configured, select Exit Setup from the Setup screen, and press
the Set button.
The GA-1121 will reboot with the updated system software and setup options.
15.
When the GA-1121 reaches the Idle screen, exit MS-DOS at the PC and remove the System
Software CD from the CD-ROM drive.
16.
Power off the copier and PC, and remove the parallel cable.