GD-1300 FAX SOFT SWITCH 5 - 2
2. Soft switch list
• When outside the set range, the default value is automatically set.
• Never change the soft switch setup which are inhibited to use.
∗
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden,
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C D E
S
W
1
1
Image quality
priority selection
Bit No.
1
2
Normal
0 0 0 0 0
Refer to User program
“RESO.PRIORITY”.
When a value outside
the set range is set,
the initial value is set.
Normal
0
0
2
Fine
0
1
0 0 0 0 0
Super fine
1
0
3
Inhibited to use
0 0 0 0 0
4
Auto/Manual
default setup
1: Manual reception
0: Automatic reception
Automatic
reception
0 0 0 0 0
Manual reception can
be set only when
external telephone is
connected.
5
Send request
protection
1: Not protected
0: Protected
Protected
0 0 0 0 0
Refer to User program
“SECURITY
SELECTION”.
6
Inhibited to use
0 0 0 0 0
7
0 0 0 0 0
8
0 0 0 0 0
S
W
2
1
Inhibited to use
0 0 0 0 0
2
0 0 0 0 0
3
0 0 0 0 0
4
0 0 0 0 0
5
Remote selection
number setup
Binary input
5
0 0 0 0 0 Refer to User program
“REMOTE
RECEPTION #”.
When a value outside
the set range is set,
the initial value is set.
6
Bit No.
Set range
5
6
7
8
0 to 9
1 1 1 1 1
7
0 0 0 0 0
8
1 1 1 1 1
S
W
3
1
Density default
setup
Bit No.
1
2
3
4
5
Medium
0 0 0 0 0 When a value outside
the set range is set,
the initial value is set.
2
Light
1
0
0
0
0
0 0 0 0 0
3
Medium
0
0
1
0
0
1 1 1 1 1
4
Dark
0
0
0
0
1
0 0 0 0 0
5
0 0 0 0 0
6
Inhibited to use
0 0 1 1 1
7
Size specification
Bit No.
7
8
Conforms to the
machine
information.
0 0 0 0 0
When set to
conformity to the
machine information,
if machine information
is uncertain, set to
centimeter size.
Centimeter size
0
0
Conforms to the machine
information.
0
1
8
Inch size
1
0
1 1 1 1 1
Conforms to the machine
information.
1
1
S
W
4
1
Recall interval in
communication
error
Binary input
1min
0 0 0 0 0
Refer to User program
“RECALL INTERVAL
(LINE ERROR)”.
When a value outside
the set range is set,
the initial value is set.
Bit No.
Set range
1
2
3
4
1 to 15min
0: Recall immediately after
cutting the line
2
0 0 0 0 0
3
0 0 0 0 0
4
1 1 1 1 1
5
Recall interval in
busy
Binary input
3min
0 0 0 0 0 Refer to User program
“RECALL INTERVAL
(BUSY)”.
When a value outside
the set range is set,
the initial value is set.
6
Bit No.
Set range
5
6
7
8
1 to 15min
0 0 0 0 0
7
1 1 1 1 1
8
1 1 1 1 1