GD-1300 FAX SOFT SWITCH 5 - 7
∗
: A = U.S.A. / B = Canada / C = U.K., Netherlands, Luxembourg, Belgium / D = Germany, Sweden,
Spain, Italy, Switzerland, Finland, Denmark, Norway / E = France
S
W
23
1
Inhibited to use
0 0 0 0 0
2
0 0 0 0 0
3
0 0 0 0 0
4
0 0 0 0 0
5
0 0 0 0 0
6
0 0 0 0 0
7
0 0 0 0 0
8
0 0 0 0 0
S
W
24
1
Inhibited to use
0 0 0 0 0
2
0 0 0 0 0
3
Specified number
reception (ANTI
JUNK FAX)
Bit No.
3
4
Not set.
0 0 0 0 0
Refer to Main menu
“ANTI JUNK FAX”.
When a value outside
the set range is set,
the initial value is set.
Not set.
0
0
4
Receive inhibit
0
1
0 0 0 0 0
5
Inhibited to use
0 0 0 0 0
6
Document output
setup in reception
1: Collective output after
completion of reception
0: Output after reception
of every page
Output after
reception of
every page (A/B)
Collective output
after completion
of reception
(C/D/E/F/G)
0 0 1 1 1
7
Inhibited to use
0 0 0 0 0
8
Automatic
reduction print
1: Allow
0: Inhibit
Allow
1 1 1 1 1
Refer to User program
“AUTO RCV
REDUCE”.
S
W
25
1
Automatic
reduction rate
setup
Binary input
10%
1 1 1 1 1
2
Bit No.
Set range
1
2
3
4
0 to 15%
0 0 0 0 0
3
1 1 1 1 1
4
0 0 0 0 0
5
Transmission end
sound tone
Bit No.
5
6
1000Hz
0 0 0 0 0
When a value outside
the set range is set,
the initial value is set.
550Hz
0
0
6
1000Hz
0
1
1 1 1 1 1
1700Hz
1
0
7
Reception end
sound tone
Bit No.
7
8
1000Hz
0 0 0 0 0
When a value outside
the set range is set,
the initial value is set.
550Hz
0
0
8
1000Hz
0
1
1 1 1 1 1
1700Hz
1
0
S
W
26
1
Read completion
sound
1: Mute
0: 1sec
1sec
0 0 0 0 0
2
Inhibited to use
0 0 0 0 0
3
Speaker volume
setup
Bit No.
3
4
Small
0 0 0 0 0
Refer to User program
“BEEPER VOLUME
(send completion
sound / receive
completion sound /
scan completion
sound / alarm sound)”
Silent
0
0
Small
0
1
4
Medium
1
0
1 1 1 1 1
Large
1
1
5
Inhibited to use
0 0 0 0 0
6
0 0 0 0 0
7
0 0 0 0 0
8
0 0 0 0 0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C D E