GD-1300 FAX SOFT SWITCH 5 - 23
3. Soft switch descriptions
SW1 No.1, No.2 Image quality priority selection
Used to select the image quality setting when pressing [Clear All]
key or during auto clear.
Default: 0 0 (Normal)
SW1 No.3 Inhibited to use
SW1 No.4 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the
power.
Default: 0 (Automatic reception)
SW1 No.5 Send request protection
Used to set enable/disable of the confidential function (inhibit to
send to erroneous destinations) in send request communication
(remote send).
The confidential function is performed by collating the number regis-
tered in this machine and the number registered in the remote
machine.
Sender number
↔
Send request allow number
Default: 0 (Protected)
SW1 No.6–No.8 Inhibited to use
SW2 No.1–No.4 Inhibited to use
SW2 No.5–No.8 Remote selection number setup
Used to set the number in binary input for remote switch receive
from external telephone.
However, "
∗
" in the remote switch number (X
∗∗
) is fixed.
Default: 5
SW3 No.1–No.5 Density default setup
Used to set the density when pressing [Clear All] key or during auto
clear.
Default: 0 0 1 0 0 (Medium)
SW3 No.6 Inhibited to use
SW3 No.7, No.8 Size specification
Used to set the size specification (AB series, inch series).
Under setting of "Follow information from machine," when command
information from the machine is uncertain, set this item to AB series.
Default: 0 1 (Conforms to the machine information.)
SW4 No.1–No.4 Recall interval in communication error
Used to set the interval for recall when communication is cut off by
an error during memory send. (Including no response from the
remote machine.)
Setting is made in binary input.
When set to 0, resend is mad immediately after completion of com-
munication.
However, the time interval set by SW21 "Interval between comple-
tion of communication and the next call" is valid.
Default: 1min
SW4 No.5–No.8 Recall interval in busy
Used to set the interval for the next call when busy tone is detected
in communication.
Setting is made in binary input.
Default: 3min
SW5 No.1, No2 Inhibited to use
SW5 No.3, No.4 G3 send data accumulation wait time
Used to set wait time for accumulation of image data before sending
image data directly.
Default: 0 0 (6sec)
SW5 No.5–No.8 Pause time setup
Used to set pause time when registering dials.
Default: 2sec
SW6 No.1 ECM
Used to set YES/NO of error resend mode.
When, however, SW43-1 (V.34 mode function) is OFF or when
SW34-1 (V.34 mode function) is ON and send is made other than
SG3, ECM setting of "NO" is valid.
Since the ECM function is essential in V.34 mode and the remote
machine may perform checking, when SW43-1 (V.34 mode function)
is ON , this function is invalid in reception.
Default: 1 (Yes)
SW6 No.2 CED signal send
Used to set YES/NO of CED signal send.
This is valid only when SW52-7 (V.34 mode function) is OFF.
This is because ANSam signal send is necessary for V.34 mode.
When set to 1, CED signal send is performed.
When set to 0, CED signal send is not performed.
Default: 1 (Yes)
S
W
109
1
Print magnification ratio adjustment
(Main scan back surface) flag
1: –
0: +
+
0
2
Print magnification ratio adjustment
(Main scan back surface)
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
S
W
110
1
Print magnification ratio adjustment
(Sub scan back surface) flag
1: –
0: +
+
0
2
Print magnification ratio adjustment
(Sub scan back surface)
Binary input
0%
0
3
Bit No.
Set range
2
3
4
5
6
7
8
0 to ±12.7%
0.1% interval
0
4
0
5
0
6
0
7
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark