GD-1300 FAX SOFT SWITCH 5 - 30
SW60 No.5–No.8 Scan effective image area sub scan
rear edge image loss (RADF back surface)
Used to set image loss in scan image area.
Image loss on the rear edge in RADF bask surface sub scan direc-
tion can be adjusted. When the set value is increased, image loss on
the rear edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW61 No.1–No.8 Inhibited to use
SW62 No.1–No.3 Inhibited to use
SW62 No.4, No.5 V.8 mode ANSam signal send time
Used to set ANSam/CED signal send time.
Default: 0 1 (4sec)
SW62 No.6–No.8 Inhibited to use
SW63 No.1–No.8 Inhibited to use
SW64 No.1–No.8 Inhibited to use
SW65 No.1–No.8 Inhibited to use
SW66 No.1–No.8 Inhibited to use
SW67 No.1–No.4 Make time (10PPS) setup
Used to set make time in dialing in 10PPS.
Setting is made in binary input in the increment of 1ms.
SW67 No.5–No.8 Inhibited to use
SW68 No.1, No.2 Line open delay time in dial test
Used to set time interval between end of dialing and opening the
line. Valid only in dial test of simulation.
Default: 0 0 (2sec)
SW68 No.3, No.4 Inhibited to use
SW68 No.5–No.8 T1 timer setup
Used to set time for connection of the line when the remote machine
does not respond in FAX communication.
The time of ITU-T standard is 35 ± 5sec.
Setting is made in binary input in the increment of 5sec.
Default: 40sec
SW69 No.1–No.8 Inhibited to use
SW70 No.1–No.3 Inhibited to use
SW70 No.4 Reception waiting time between frames
Used to set reception wait time between frames.
Default: 0 (3.4sec)
SW70 No.5, No.6 Preamble send time of 300bps
Used to set preamble send time of 300bps.
Default: 0 1 (1.0sec)
SW70 No.7, No.8 RCP send times
Used to set number of times of RCP frame send.
Default: 0 0 (3 times)
SW71 No.1–No.8 Inhibited to use
SW72 No.1 EYE-Q check
Used to set TCF check in TCF reception.
When set to 1, check is made only with EYE-Q value (EQM value).
Therefore, TCF check is loosely made.
When set to 0, check is made with received data and EYE-Q value
(EQM value).
Default: 0 (0 reception & EYE-Q check)
SW72 No.2 ERR frame reception operation
Used to set operations when an image with an error frame is
received.
Default: 0 (Not continue process. (Error))
SW72 No.3, No.4 Waiting time for CED/ANSam send
start
Used to set waiting time from when the line is connected and the
machine enters FAX receive state to when CED/ANSam signal is
send to the line.
Default: 0 0 (2.25sec)
SW72 No.5 RTC EOL send times
Used to set number of times of RTC EOL send.
Default: 1 (6 times)
SW72 No.6 Inhibited to use
SW72 No.7, No.8 CNG send start
Used to set CNG send time.
Default: 0 0 (0.5sec)
SW73 No.1–No.8 Inhibited to use
SW74 No.1–No.4 Print effective image area sub scan
lead edge void
Used to set print image area void.
The void amount on the lead edge in the sub scan direction can be
adjusted. When the set value is increased, the void amount on the
lead edge is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 32 lines
SW74 No.5–No.8 Inhibited to use
SW75 No.1 Manual calibration setting when sending
Setting to execute the manual calibration or not when sending.
In case of an abnormal current waveform, the auto calibration fails
and the DTFM signal is deformed. This setting provides the counter-
measure against that problem.
Default: 0 (OFF)
SW75 No.2 Manual calibration setting when a signal
arrives
Setting to execute the manual calibration or not when a signal
arrives.
In case of an abnormal current waveform, the auto calibration fails
and the transmission is affected. This setting provides the counter-
measure against that problem.
Default: 0 (OFF)
SW75 No.3, No.4 Communication end sound (Buzzer
sound length) setting
Used to set the length of communication end buzzer sound in com-
munication.
Default: 0 0 (3sec)
Default: 40ms (North America) /
33ms (U.K., Netherlands, Luxembourg, Belgium, France) /
41ms (Germany, Sweden, Spain, Italy, Switzerland,
Finland, Denmark, Norway)