background image

 

 
 

 

SETUP – MK2003GAH (HDD1364) HARD DISK DRIVE 
 

 

Caution

: Your Hard Disk Drive is a precision device and even a small drop onto any surface can cause 

damage. Electronstatic discharge can also damage the drive. You should ground yourself prior to handling the 
drive.  

 

Figure 1. MK2003GAH Side View

Installation Notes

  

 

Do not apply any force to the top cover, except the screw areas on top cover. Maximum force to the 

specified area is 2N.  

 

important Note: Disconnect power from your computer system before beginning 
installation

 

 

Summary of Contents for HDD1364

Page 1: ...TOSHIBA AMERICA INFORMATION SYSTEMS STORAGE DEVICE DIVISION IRVINE CALIFORNIA MK2003GAH HDD1364 1 8 INCH HARD DISK DRIVE USER MANUAL Rev 02 11 2006 ...

Page 2: ...CONTENTS Introduction 1 Setup 2 Using the HDD 3 Specifications 4 Drive Connectors 6 ...

Page 3: ...atures 1 8 sized drive 2 Platter 20 Gigabytes 8mm High 15ms Average Seek Time ATA 2 5 Interface Ultra DMA 100 512KB Buffer Rotational speed of 4 200rpm MTTF 300 000 Hours Toshiba defines a megabyte MB as 1 000 000 bytes and a gigabyte GB as 1 000 000 000 bytes ...

Page 4: ...tronstatic discharge can also damage the drive You should ground yourself prior to handling the drive Figure 1 MK2003GAH Side View Installation Notes Do not apply any force to the top cover except the screw areas on top cover Maximum force to the specified area is 2N important Note Disconnect power from your computer system before beginning installation ...

Page 5: ...3 USING THE HARD DISK DRIVE MK2003GAH HDD1364 HARD DISK DRIVE Backing up Data Files To avoid data loss regularly back up the data files on the hard disk drive ...

Page 6: ...ec Interleave Factor 1 1 Toshiba defines a megabyte MB as 1 000 000 bytes and a gigabyte GB as 1 000 000 000 bytes Number of Disks 2 Number of Data Heads 4 Track Density TPI 2237 56 8k Logical Cylinders 16 383 Logical Heads 16 Logical Sectors track 63 Bytes per Sector 512 Logical Blocks LBA 39 062 520 Reliability Preventative maintenance None Non recoverable read errors 1 error per 1013 bits read ...

Page 7: ...dards Underwriters Laboratories UL 1950 Canadian Standard Association CSA C22 2 No 950 TUV Rheinland EN 60 950 EMC EN50081 1 EN50081 1 1992 EN55022 1994 Class B EN61000 3 2 1995 EN61000 3 3 1995 EMC EN50082 1 EN61000 4 2 1995 EN61000 4 3 1998 ENV50204 1995 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 BSMI 3902C799 ...

Page 8: ...RS MK2003GAH HDD1364 HARD DISK DRIVE Figure 1 MK2003GAH HDD INTERFACE CONNECTOR Interface Connector Drive Side Connector MCD D50 Series by DDK Connectors Recommended Host Side Connector MCD D50 Series by DDK Connectors ...

Page 9: ...DD 13 15 DD 1 16 DD 14 17 DD 0 18 DD 15 19 GROUND 20 OPEN 21 DMARQ 22 GROUND 23 DIOW STOP 24 GROUND 25 DIOR DMARDY HSTROBE 26 GROUND 27 IORDY DMARDY DSTROBE 28 CSEL 29 DMACK 30 GROUND 31 INTRQ 32 IOCS16 33 DA1 34 PDIAG 35 DA0 36 DA 2 37 CS0 38 CS1 39 DASP 40 GROUND 41 3 3V LOGIC 42 3 3V MOTOR 43 GROUND 44 RESERVED Note Symbol in front of signal indicates negative logic ...