CAUTION

• Please read this installation manual carefully before installing the unit. It contains

further important instructions for proper installation.

• Exposure of unit to water or other moisture before installation could result in

electric shock. Do not store it in a wet basement or expose to rain or water.

• After unpacking the unit, examine it carefully for possible damage.
• Do not install in a place that can increase the vibration of the unit. Do not

install in a place that can amplify the noise level of the unit or where noise and
discharged air might disturb neighbors.

• This appliance must be connected to the main power supply by means of a

circuit breaker depending on the place where the unit is installed. Failure to do
so may cause electrical shock.

• Follow the instructions in this installation manual to arrange the drain pipe for

proper drainage from the unit. Ensure that drained water is discharged.
Improper drainage can result in water leakage, causing water damage to
furniture.

• Tighten the flare nut with a torque wrench using the prescribed method. Do not

apply excess torque. Otherwise, the nut may crack after a long period of usage
and it may cause the leakage of refrigerant.

• Wear gloves (heavy gloves such as cotton gloves) for installation work. Failure

to do so may cause personal injury when handling parts with sharp edges.

• Do not touch the air intake section or the aluminum fins of the outdoor unit. It

may cause injury.

• Do not install the outdoor unit in a place which can be a nest for small animals.

Small animals could enter and contact internal electrical parts, causing a failure
or fire.

• Request the user to keep the place around the unit tidy and clean.
• Make sure to conduct a trial operation after the installation work, and explain

how to use and maintain the unit to the customer in accordance with the manual.
Ask the customer to keep the operation manual along with the installation
manual.

01_1120551201-1 EN.indd   6

01_1120551201-1 EN.indd   6

5/18/2560 BE 3:12 PM

5/18/2560 BE   3:12 PM

Summary of Contents for HWS-455H-E

Page 1: ...Outdoor unit HWS 455H E AIR TO WATER HEAT PUMP INSTALLATION MANUAL ENGLISH ...

Page 2: ...Refrigerant Piping Connection Evacuating ELECTRICAL WORKS Wiring Connection Power Supply and Connecting Cable Connection Power supply input Wiring Diagram OTHERS Gas Leak Test Earthing Finishing Test run Annual maintenance Air to water heat pump operating conditions CONTENTS EN 1 7 7 7 8 8 9 10 10 10 10 11 11 11 11 11 11 11 ...

Page 3: ...se of this unit can result in a high possibility of severe injury 1 or death WARNING It indicates that incorrect use of this unit may cause severe injury or death CAUTION It indicates that incorrect use of this unit may cause personal injury 2 or property damage 3 1 A severe injury refers to blindness injury burns hot or cold electrical shock bone fracture or poisoning that leaves aftereffects and...

Page 4: ...e sizes of charging port connecting sections on the main unit are different from those for the conventional refrigerant and different size tools are also required For connecting pipes use new and clean piping materials with high pressure withstand capabilities designed for R410A only and ensure that water or dust does not enter Moreover do not use any existing piping as its pressure withstand may ...

Page 5: ... RADIATORS HEATERS FURNACE STOVES ETC WHEN MOVING THE AIR TO WATER HEAT PUMP FOR INSTALLING IT IN ANOTHER PLACE AGAIN BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT R410A WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE IF AIR OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AN...

Page 6: ...he hydro outdoor units Midway connection stranded wire and single wire connections are not allowed Improper connection or fixing may cause a fire Wiring between the hydro unit and outdoor units must be well shaped so that the cover can be firmly placed Improper cover installation may cause increased heat fire or electrical shock at the terminal area Be sure to use only approved accessories or the ...

Page 7: ...air absorbed and abnormal high pressure inside the refrigeration cycle and resulting burst or injury Do not modify the power cable connect the cable midway or use a multiple outlet extension cable Doing so may cause contact failure insulation failure or excess current resulting in fire or electrical shock Do not use any refrigerant different from the one specified for complement or replacement Oth...

Page 8: ...harged Improper drainage can result in water leakage causing water damage to furniture Tighten the flare nut with a torque wrench using the prescribed method Do not apply excess torque Otherwise the nut may crack after a long period of usage and it may cause the leakage of refrigerant Wear gloves heavy gloves such as cotton gloves for installation work Failure to do so may cause personal injury wh...

Page 9: ...ION DIAGRAM OF OUTDOOR UNITS INSTALLATION DIAGRAM OF OUTDOOR UNITS Part code Parts name Q ty A Refrigerant piping Liquid side Ø6 35 mm Gas side Ø12 7 mm One each B Pipe insulating material polyethylene foam 6 mm thick 1 C Putty PVC tapes One each Optional Installation Parts 600 mm or more 100 mm or more 100 mm or more 600 mm or more 600 mm or more Remark Some pictures might be different from the a...

Page 10: ... A place full of machine oil A saline place such as the coast A place full of sulfide gas A place where high frequency waves are likely to be generated as from audio equipment welders and medical equipment Strong wind Incused line Flare at hydro unit side Flare at outdoor unit side Flare nut Half union Externally threaded side Internally threaded side Use a wrench to secure Use a torque wrench to ...

Page 11: ...d liquid sides 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves Using a vacuum pump Packed valve at liquid side Service port Valve core Setting pin Packed valve at gas side Vacuum pump Vacuum pump adapter for counter flow prevention For R410A only Charge hose For R410A only Handle Hi Keep full closed Manifold valve Pressure gauge Compound pressure g...

Page 12: ... Block 0 1 0 1 0 1 0 1 30 30 40 40 L N 1 2 3 1 2 3 L N Connecting cable Earth line Earth line Connecting cable Connecting cable connect to terminal block 1 2 3 Power supply terminal block L N Power cord Power cord Terminal block CAUTION 1 The power supply must be same as the rated of air to water heat pump 2 Prepare the power source for exclusive use with air to water heat pump 3 Circuit breaker m...

Page 13: ...d which may damage the compressor or other components If there is a leak at a connection air can be sucked in and the internal pressure further increases which may cause a burst or injury Operate the air to water heat pump in the correct procedure as specified in the Owner s Manual Please refer to the Hydro unit installation manual for the detail of the test run For an air to water heat pump syste...

Page 14: ......

Reviews: