26
( 2 ) 1P SR (1 Pulse Trigger Sync Reset)
Charge begins to accumulate after the trigger input to the RGB terminal, the vertical sync signal is reset and
frame images are output.
(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.
About 1
µ
s
Exposure completion
0 to 1H*
3
Exposure period*
2
Video output
VIDEO INDEX
VD OUT
Trigger*
1
796H (Partial scanning OFF)
387H (Partial scanning 60fps)
258H (Partial scanning 90fps)
Negative polarity mode
Positive polarity mode
IK-TF7(E)
2004.03.24, 0:59 PM
Page 26
Adobe PageMaker 6.5J/PPC