MP118 MEDIA SETTINGS
Load INI file to the Gateway
Installation Manual June, 2011
12-5
Coders
12. Select
Protocol Configuration > Protocol Definition > Coders
13. Ensure the following:
Coder Name
G.711 mu-law
Packetization Time
= 20
Rate
= 64
Silence Suppression
= Disabled
and
Coder Name
G.729
Packetization Time
= 20
Rate
= 8
Silence Suppression
= Disabled
14. Click on the
Submit
button.
SIP Advanced Parameters
15. Select
Protocol Configuration > SIP Advanced Parameters >
Advanced Parameters.
Set the
Disconnect on broken connection
= No
Set
Enable current disconnect
= Enabled.
16. Click on
Submit
.
IP Profile Settings
17. Select
Protocol Configuration > Coders And Profile Definitions >
IP Profile Settings
Set the
Disconnect on broken connection
= No
18. Click on
Submit
.
Routing Table
19. Select
Protocol Configuration > Routing Tables > Routing
General Parameters
.
Set
Enable alternate routing
= Enabled
20. Click on
Submit
.
Summary of Contents for IPedge
Page 1: ...TOSHIBA Telecommunication Systems Division Installation Manual Title Page June 2011 ...
Page 18: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 88: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 140: ...MEDIANT 1000 CONFIGURATION IPedge Configuration 12 20 Installation Manual June 2011 ...
Page 196: ...THIS IS THE END OF THE DOCUMENT ...