EM SERVER POWER SUPPLIES
IPMI FRU Address
2-6
Installation Manual June, 2011
Figure 2-5 IP
edge
EM Server - Rear panel Connectors
EM SERVER POWER
SUPPLIES
The IP
edge
EM Server has dual redundant power supplies. In the event
of a power supply failure the failed supply will go off-line, the surviving
supply will supply all of the power and allow the system to continue
operation without interruption.
IPMI FRU Address
The power supply module IPMI FRU addresses are 72 and 70. The
modules, as viewed from the rear of the chassis 70 (binary 1110 000) on
the right, 72 (binary 1110 001) on the left or outside.
Power Supply Failure
If either of the power supply modules fail, the Universal Information (UID)
LED on the control panel will blink slowly to indicate a failed power supply
module. The UID LED will continue to blink until the failed module has
been replaced. Also, the power supply LED, on the rear panel will change
from green to amber on the failed unit. The failed unit will issue a
continuous beep tone. The power supply modules have a hot-swap
capability, you can replace the failed module without powering down the
system.
RACKMOUNT
INSTALLATION
The IP
edge
servers mount into standard 19 inch EIA Universal Spacing
racks and cabinets.
EC SERVER RACKMOUNT
The IP
edge
EC Server is 15 inches (381 mm) deep. Rails are not
included with the server chassis. The optional mounting rails are
designed for installation in two-post or four-post racks.
PS/2
Mouse
Keyboard
UID
UID
Button
LED
LAN 1 LAN 2
COM 1 VGA
Redundant Power
Supplies
IPMI Connector
USB
PS #1
PS #2
PS1 LED
PS2 LED
Summary of Contents for IPedge
Page 1: ...TOSHIBA Telecommunication Systems Division Installation Manual Title Page June 2011 ...
Page 18: ...This page is intentionally left blank ...
Page 32: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 74: ...This page is intentionally left blank ...
Page 78: ...This page is intentionally left blank ...
Page 88: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 140: ...MEDIANT 1000 CONFIGURATION IPedge Configuration 12 20 Installation Manual June 2011 ...
Page 196: ...THIS IS THE END OF THE DOCUMENT ...