Hardware Diagnostics
HW Diagnostics Program Main Menu
268
❖
11. SAF-TE TEST checks the SAF-TE function and the status LED of the hard disk
drives.
SAF-TE TEST (SAF) Error Log
- 01. SAF-TE test detects the SAF-TE controller and checks the operation by flashing
the LED for each hard disk drive.
The test detects the SAF-TE controller first and shows the connecting destination of
the detected SAF-TE controller (host number, SCSI ID, and channel number) with
model name. For example:
--HT-ID----CH--VENDOR-PRODUCT-------FAN--PS--SLOT
XX XX XX XXXXX XXXX XX XX XX
After detecting the SAF-TE controller, the following message appears:
SAF-TE LED Steady ON (Faulty Flag) Press any key
Check that all LEDs of the hard disk drives are lit orange. Then press
Enter
.
The following message appears:
SAF-TE LED Blinking (Rebuilding Flag) Press any key
DD
Sense data (2 byte)
EE
Sense data (12 byte)
Sense Key
FF
Sense data (13 byte)
Expansion Sense code
GG
Sense data (14 byte)
Expansion Sense code
The CD-ROM test tests only one IDE CD-ROM. The CD_ROM test searches for
the CD-ROM device in the following order: IDE (PrM, PrS, ScM, ScS), SCSI (ID0,
ID1...). The CD-ROM device encountered first is the device tested.
Status
Error name
Meaning
01
SAF-TE TEST ERROR
SAF-TE controller has not been
detected
Summary of Contents for Magnia 3310
Page 1: ......