Connecting Hardware Devices
Cooling fans
56
Removing and replacing a primary or redundant exhaust fan
This section provides instructions for removing and installing either the primary exhaust
fan or a redundant exhaust fan for Toshiba Magnia 3310/3310R servers. If you remove a
primary exhaust fan for any reason, you must replace it before operating the server;
otherwise, the server will overheat and may be damaged.
If the server is in operation, shut it down, then remove the access panel. For detailed
instructions, read Steps 1 through 4 in
Maintenance overview
on page 50.
1
Disconnect the exhaust fan module cable from the motherboard. If the exhaust fan
module has a redundant exhaust fan installed, also disconnect the redundant fan
cable from the motherboard.
Disconnecting the exhaust fan module cables
Removing a cooling fan while the server is on could result in electric shock and
shorten the service life of the fan and the server.