To improve the cooling/heating performance, change 
the louver angle for each operation.

To set the air discharge direction 

to forward using a front air 
discharge unit (sold separately)

CAUTION

When applying a front air discharge unit to the 
indoor unit, the 2-way air discharge function 
(f downward) is not available.
Such use may lower the air temperature and cause 
water leakage.

For details on the installation, read the installation 
manual that comes with a front air discharge unit (sold 
separately).

When using a front air discharge unit (sold 
separately) for an indoor unit of the 1-way cassette 
type, follow the procedure below to change 
discharge direction:

Vertical adjustment

NOTE

1. When sending air downward, bend the louvers 

evenly as shown in the following figure.
If the air flow is blocked, water droplets may fall 
down from the air discharge.

2. Set the angle of the louver to 40° or lower.

If the angle is over 40°, droplets may fall down.

Horizontal adjustment

NOTE

When adjusting air direction horizontally, arrange the 
angles of the vertical grilles gradually as shown in the 
following figure.
If the air flow is blocked, water droplets may fall down 
from the air discharge.

When cooling

Move the louver manually and point it horizontally to 
send cool air across the entire room.

When heating

Move the louver manually and point it downward to 
send heated air to the floor.

Louver

Use the vertical grille behind the louver to even the 
room temperature.

Louver

NO GOOD

GOOD

40° or lower

Vertical grille

Vertical grilles

NO GOOD

GOOD

„

Ceiling type

Vertical adjustment

• The louver automatically points upward when 

running is stopped.

• In pre-heating mode, the louver points upward.

The swing indication appears on the remote 
controller even in pre-heating mode, but the actual 
swing starts only after pre-heating is complete.

Horizontal adjustment

„

1-way cassette (YH series), 
and floor standing types

Setting the direction and swinging

1

Push the 

 button during running.

If 1 remote controller controls 2 or more indoor 
units, you can configure the direction setting for 
each unit individually.

Push the

 

 

button again while the louver 

is swinging.

2

You can stop the louver in your preferred 
position.

Unit select

• When two or more indoor units are controlled with 

one remote controller, the louver direction can be set 
for each indoor unit by selecting them individually.

• To set louver direction individually, push the 

 

button (left side of the button) to display an indoor 
unit number in the control group. Then set the louver 
direction of the displayed indoor unit.

• When no indoor unit number is displayed, all indoor 

units in the control group can be controlled 
simultaneously.

• Each time you push the 

 (left side of the 

button), the indication changes as follows:

When cooling

Point the louver horizontally to send cool air across the 
entire room.

When heating

Point the louver downward to send heated air to the 
floor.

When adjusting louver direction horizontally, point the 
vertical grille inside the horizontal louver in your 
preferred direction.

SWING/FIX

SWING/FIX

1,2

SET

TIME

TIMER SET

TEST

FILTER

LL

RESET

TEMP.

CL

FAN

SAVE

A

A

SWING/FIX

VENT

MODE

ON / OFF

UNIT  LOUVER

Unit select

UNIT  LOUVER

UNIT  LOUVER

Unit No. 

1-4

No 

display

Unit No. 

1-1

Unit No. 

1-2

Unit No. 

1-3

31-EN

32-EN

Summary of Contents for MAP1404FT8-E

Page 1: ... commercial use Outdoor Unit Model name MMY MAP0804FT8 E MMY MAP1004FT8 E MMY MAP1204FT8 E MMY MAP1404FT8 E MMY MAP0804FT8Z E MMY MAP1004FT8Z E MMY MAP1204FT8Z E MMY MAP1404FT8Z E MMY MAP0804FT8ZG E MMY MAP1004FT8ZG E MMY MAP1204FT8ZG E MMY MAP1404FT8ZG E ...

Page 2: ...nt destruction of the ozone layer This appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Contents 1 Precautions for safety 3 2 Part names of outdoor and indoor units 5 3 ...

Page 3: ...oners made by Toshiba Carrier Corporation He or she has been trained to install repair maintain relocate and remove the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualified service pers...

Page 4: ...ervice person Do not climb onto or place objects on top of the outdoor unit You may fall or the objects may fall off of the outdoor unit and result in injury Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is operated with a combustion appliance in the same place be car...

Page 5: ...aning the air conditioner in an improper manner may cause damage to plastic parts insulation failure of electric parts etc and result in a malfunction In the worst case it may result in water leakage electric shock smoke emission and fire Do not wash air conditioners with pressure washers Electric leaks may cause electric shocks or fires 1 Refer to the Definition of Qualified Installer or Qualifie...

Page 6: ...er s manuals that come with the indoor units Console Type MML AP NH For details on these models read the owner s manuals that come with the indoor units 2 Part names of outdoor and indoor units Outdoor unit Indoor unit 4 Way Cassette Type Compact 4 Way cassette Type Air intake Provided on the four sides Fixing leg Air discharge Warm air comes out when cooling and cool air when heating Power wire h...

Page 7: ... control box Return air grille Air in the room is taken in through here Concealed Duct Standard Type MMD AP 4H MMD AP 6H Concealed Duct High Static Pressure Type MMD AP018 H to AP048 H MMD AP072 H to AP096 H Air filter Filters out dust Inside the return air grille Air discharge The air discharge duct is connected Earth screw Equipped on the electrical control box Return air grille Air in the room ...

Page 8: ... air directions Earth screw Return air grille Air in the room is taken in through here Floor Standing Concealed Type Floor Standing Type Air discharge Drain funnel with strainer Accessory to be attached at the site Air filter Filters out dust Inside the return air grille Front panel lower Earth screw Equipped on the electrical control box Air intake Air in the room is taken in through here Dischar...

Page 9: ...cator Displayed when the remote controller sensor is used 12 Pre heat indicator Displayed when the heating mode is energized or defrost cycle is initiated While this indication is displayed the indoor fan stops or operate in fan mode 13 No function indicator Displayed when the function requested is not available on that model 14 Fan speed indicator Indicates the selected fan speed 15 Louver Number...

Page 10: ...ealed and floor standing cabinet fresh air intake types 8 Operation lamp Lights up during running Blinks when an error occurs or the protective device activates 9 button Turns on the unit when pushed and turns off when pushed again 10 button Operation mode select button Selects desired operation mode 1 8 3 5 2 9 10 6 7 12 4 11 SWING FIX 11 button Unit Louver select button Selects a unit number lef...

Page 11: ...rature is a target of room temperature The fan speed selection function is not available for the concealed duct high static type Fan speed is fixed and the indicator is fixed to High SET TIME TIMER SET TEST FILTER RESET TEMP CL FAN SAVE SWING FIX VENT MODE ON OFF UNIT LOUVER 1 3 2 Heat Dry Cool Fan Dehumidify Auto Low Medium High Auto Changing the set temperature 1 Push the TEMP buttons Push to in...

Page 12: ...ng near machines emitting high frequency waves Not suitable for chemical plants such as liquefied carbon dioxide refrigerant plants Do not install the air conditioner in locations where iron or other metal dust is present If iron or other metal dust adheres to or collects on the interior of the air conditioner it may spontaneously combust and start a fire A failure may occur in certain locations s...

Page 13: ... once per one hour to protect the machines Protective device High pressure switch The high pressure switch stops the air conditioner automatically when excessive load is applied to the air conditioner If the protective device activates the unit s running stops and the operation lamp blinks When the protective device activates the indicator and the check code are displayed on the remote controller ...

Page 14: ...tion the louver does not stop as it directs downward If stopping the louver as it directs downward during swing operation it stops after moving to the third position from the highest position Unit select When two or more indoor units are controlled with one remote controller the louver direction can be set for each indoor unit by selecting them individually To set louver direction individually pus...

Page 15: ... FIX UNIT LOUVER No display Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 Swing code Swing Horizontal Downward Downward Horizontal Downward Downward Horizontal Horizontal Cyclic swing Recommended for cooling All four louvers swing at different times like waves Setting the louver lock 1 Push and hold the button right side of the button for at least 4 seconds while running is stopped blinks When n...

Page 16: ...Drain pipe Electrical control box Direction SET DATA Direction setting 0000 Smudging reduction position reduces ceiling smudging factory default 0002 Cold draft position Less directly expose your body to cool air 0000 SET DATA UNIT LOUVER Unit No 1 1 Unit No 1 2 Unit No 1 3 Unit No 1 4 No display 4 way cassette type The louver automatically closes when running is stopped In pre heating mode the lo...

Page 17: ... GOOD GOOD Ceiling type Vertical adjustment The louver automatically points upward when running is stopped In pre heating mode the louver points upward The swing indication appears on the remote controller even in pre heating mode but the actual swing starts only after pre heating is complete Horizontal adjustment 1 way cassette YH series and floor standing types Setting the direction and swinging...

Page 18: ...tly and point them in your preferred directions 1 2 In this case do not use the auto swing function Floor standing cabinet type Changing the air discharge Follow the procedure below to change the air discharge 1 Remove the two fixing screws of the air discharge The fixing screws are to be reused 2 Insert your hand into the air discharge and pull it up slightly then remove the air discharge from th...

Page 19: ...a long time is bad for your health Cooling operation Outdoor temperature 10 C to 43 C Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 20 C to 15 5 C Wet bulb temp Room temp...

Page 20: ...apter Wipe with a dry soft cloth If heavily stained wipe off dirt with a cloth soaked in lukewarm water Do not use water to wipe the remote controller Do not use benzine thinner scouring powder chemical cloth etc as those may cause deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then ...

Page 21: ...y Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to LOW MED and is the operation mode set to FAN Is the setup temp the appropriate temperature Is outdoor temperature out of operation temperature range CAUTION If any of the follow...

Page 22: ...rized Representative TCF holder Nick Ball Toshiba EMEA Engineering Director Toshiba Carrier UK Ltd Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type MMY MAP0804FT8 E MMY MAP1004FT8 E MMY MAP1204FT8 E MMY MAP1404FT8 E MMY MAP0804FT8Z E MMY MAP1004FT8Z E MMY MAP1204FT8Z E M...

Page 23: ... manufacturer TOSHIBA CARRIER CORPORATION Address city country 336 Tadehara Fuji shi Shizuoka ken 416 8521 Japan Name of the Importer Distributor in EU Toshiba Carrier UK Ltd Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Reviews: