136
Ca
use
Che
c
k co
de
na
m
e
Che
ck cod
e
Ou
td
oor te
mp se
nsor miswir
ing
(TE, T
L
)
1
. Mi
si
ns
tall
ati
on an
d mi
sc
onn
ec
tion
of T
E
sen
sor
and
T
L
s
e
ns
or
2
.
Resistance characteristics failure of TE sensor and TL sensor
3
. Outdoo
r
P.C. b
oard (I/F
) trouble
Cause
Check cod
e
n
a
me
Ch
eck co
de
Outdoor
p
ressure
sensor
mis
w
ir
ing (PD
, PS)
1. High-pressure PD sensor and low pressure sensor
PS are exchanged
2. Output voltage of each sensor is zero
Are co
nn
ec
tio
n
o
f
PD sensor and Ps
se
ns
or
co
nn
e
c
to
rs
c
o
rre
ct
?
No
Ye
s
Are
ou
tp
ut
vol
tag
e
c
h
a
rac
te
ri
st
ic
s
of PD sensor and PS
se
ns
or
no
rm
a
l?
No
Ye
s
Are PD / PS
ou
tp
u
t v
a
lu
es
PD>PS during
co
mp
re
s
s
or
o
p
er
a
ti
o
n?
No
Yes
Che
c
k
outd
oor I/F P
.C. boa
rd
.
Failure
Repl
ace
Ch
e
ck c
o
m
p
re
ss
o
r
Sens
or failure
Rep
lac
e
Cor
re
ct c
o
nn
ec
tion
of c
o
nne
c
to
rs
.
PD sensor: CN501, Red
PS sensor: CN500, White
(1
) Pr
es
s
u
re
(
C
hec
k j
o
in
t)
by
pr
ess
u
re
g
auge
(2)
Pr
es
s
ur
e di
spl
ay
on 7
-s
egm
ent d
is
pla
y
(3
) O
u
tpu
t vo
ltag
e of
I/F P.C.
board
If
(
1
) a
n
d (2
), (3) a
re
d
iff
e
re
n
t,
a
n
er
ro
r
o
f p
re
s
s
u
re
s
e
ns
or it
sel
f i
s
c
o
ns
id
ered.
If
(2
) a
n
d
(
3
) a
re
d
if
fer
e
n
t,
c
hec
k
in
ter
fac
e
P
.C.
bo
ard.
Val
u
e c
a
n
be c
onfi
rm
ed b
y
7
-segm
ent
d
is
p
lay
f
u
n
c
tion
on o
u
tdo
o
r
I/F P.C.
boar
d.
PD SW01 / 02 / 03 = 1/1/2
PS SW01 / 02 / 03 = 1/2/2
A
re ins
tal
led
pos
iti
ons
o
f T
E
s
e
ns
or
an
d
T
L
s
e
ns
or
corr
ec
t?
Ar
e
co
nn
ec
ti
o
n
o
f TE
se
ns
or
co
n
n
e
c
to
r
an
d TL
s
en
s
o
r c
o
nn
ec
to
r
n
o
rm
al
?
Cor
rec
t in
sta
lle
d po
si
tion
s o
f
T
E
sen
sor
an
d T
L s
ens
or
.
Cor
rec
t co
nnec
ti
on of
co
n
n
ec
to
rs
.
No
Yes
Outd
oor I/F
P.C. b
o
ar
d
T
E
se
nso
r
: CN520
, Gr
ee
n
T
L
sen
s
or
: CN523, Whi
te
No
Ye
s
Are service
valves of gas pipe and
liquid pipe of outdoor unit
fully opened?
No
Yes
Op
en s
e
rv
ic
e
va
lv
es
full
y.
4. 4-way va
lv
e trouble
Ch
eck ou
tdoor I/F P
.C. bo
ard.
Failure
Rep
lac
e
TE se
nso
r:
Outd
oo
r h
e
a
t exch
an
ge
r te
m
p
sen
sor
T
L
s
e
n
s
or
:
T
e
m
p
. s
e
ns
o
r be
tw
e
e
n
service
valves
of
liqu
id
pipe
and
P
M
V
1
/
2
* Se
e “
O
ut
do
or
u
nit
t
e
mp
era
tur
e s
e
ns
o
r c
h
ar
ac
te
ri
s
tic
s
”
on
“
9
-7
. Se
ns
o
r c
h
ar
a
c
te
ri
s
tic
s
”.
A
re
r
e
si
st
a
n
c
e
c
ha
rac
teri
st
ic
s of
T
L
se
ns
or
an
d
T
E
se
ns
or
no
rma
l?
No
Ye
s
Sens
or failure
Rep
lac
e
Yes
No
Check and replace 4-way
valve and coil.
Does discharge
refrigerant gas bypass
to suction side through
4-way valve?
126
A10-1510.indb 126
A10-1510.indb 126
2016/04/08 17:21:13
2016/04/08 17:21:13
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk